Tools Hand | Take ind. Ext. 3x32a+t v 3h ip67 steck
₲174,000
Ref.: 949433
- Location
- Mburucuya
- Price
- ₲174,000
Location
Mburucuya
Published
18/04/2023
Details
They are the only Plugs manufactured in Brazil for specific use in Electronic Containers.
They follow the main international standards, being used in all ports of the world.
Primary materials:
Housing, Lodging, Pressing and Tension Relief: Self-extinguishing Thermoplastic (C.S.A. C-22.2 n° 6 and U.L. 94 HB-Mil spec ).
Traba-Subtapa and Tuerca Tape Work: Polyamide 6.6.
Seals and Guarniciones: SBR (Neoprene under consultation).
Terminals: Solid brass.
Operation temperature:
0 / 120°C continuous work.
200°C (30 minutes).
Construction:
According to NBR IEC , IEC , DIN , DIN , CEE 17-BS4343 and VDE 0623 CE , NFC SEMKO 117.
Maximum work voltage:
690 Volts RMS - According to NBR IEC
Identification of Terminals:
According to U.L., CSA and NBR IEC
Arc Resistance:
According to C.S.A., C (1990)
Highly insulating (up to 750V - 500Hz)
Dieléctrica Rigidity
NBR IEC
Impact Resistance:
According to C.S.A. C22.2 No. 182-1 paras. 7.4.2 and 7.4.4
Abrasion resistance:
According to C.S.A. C22.2 No. 182-1 paras. 7.4.3 and 7.4
Estanqueity:
The water test according to C.S.A C22.2 - Specification 943 NBR IEC - 18(d)
Cable protection:
According to C.S.A. C. No. 182-1 paras. 7.3
Type of Cables:
According to U.L.62 and C.S.A.C22.2 n° 49
Corrosion Resistance: (Plastic Parts)
Salt Spray, Alcohol, Oil, Solvents, Lubricants, Fats, Acid Media, Alkaline and Other Chemical Agents.
Nickel Contacts:
Add NQ after the code
*Merely illustrative image
They follow the main international standards, being used in all ports of the world.
Primary materials:
Housing, Lodging, Pressing and Tension Relief: Self-extinguishing Thermoplastic (C.S.A. C-22.2 n° 6 and U.L. 94 HB-Mil spec ).
Traba-Subtapa and Tuerca Tape Work: Polyamide 6.6.
Seals and Guarniciones: SBR (Neoprene under consultation).
Terminals: Solid brass.
Operation temperature:
0 / 120°C continuous work.
200°C (30 minutes).
Construction:
According to NBR IEC , IEC , DIN , DIN , CEE 17-BS4343 and VDE 0623 CE , NFC SEMKO 117.
Maximum work voltage:
690 Volts RMS - According to NBR IEC
Identification of Terminals:
According to U.L., CSA and NBR IEC
Arc Resistance:
According to C.S.A., C (1990)
Highly insulating (up to 750V - 500Hz)
Dieléctrica Rigidity
NBR IEC
Impact Resistance:
According to C.S.A. C22.2 No. 182-1 paras. 7.4.2 and 7.4.4
Abrasion resistance:
According to C.S.A. C22.2 No. 182-1 paras. 7.4.3 and 7.4
Estanqueity:
The water test according to C.S.A C22.2 - Specification 943 NBR IEC - 18(d)
Cable protection:
According to C.S.A. C. No. 182-1 paras. 7.3
Type of Cables:
According to U.L.62 and C.S.A.C22.2 n° 49
Corrosion Resistance: (Plastic Parts)
Salt Spray, Alcohol, Oil, Solvents, Lubricants, Fats, Acid Media, Alkaline and Other Chemical Agents.
Nickel Contacts:
Add NQ after the code
*Merely illustrative image