They are the only Plugs manufactured in Brazil for specific use in Electronic Containers.
They follow the main international standards, being used in all ports of the world.
Primary materials:
Housing, Lodging, Pressing and Tension Relief: Self-extinguishing Thermoplastic (C.S.A. C-22.2 n° 6 and U.L. 94 HB-Mil spec ).
Traba-Subtapa and Tuerca Tape Work: Polyamide 6.6.
Seals and Guarniciones: SBR (Neoprene under consultation).
Terminals: Solid brass.
Operation temperature:
0 / 120°C continuous work.
200°C (30 minutes).
Construction:
According to NBR IEC , IEC , DIN , DIN , CEE 17-BS4343 and VDE 0623 CE , NFC SEMKO 117.
Maximum work voltage:
690 Volts RMS - According to NBR IEC
Identification of Terminals:
According to U.L., CSA and NBR IEC
Arc Resistance:
According to C.S.A., C (1990)
Highly insulating (up to 750V - 500Hz)
Dieléctrica Rigidity
NBR IEC
Impact Resistance:
According to C.S.A. C22.2 No. 182-1 paras. 7.4.2 and 7.4.4
Abrasion resistance:
According to C.S.A. C22.2 No. 182-1 paras. 7.4.3 and 7.4
Estanqueity:
The water test according to C.S.A C22.2 - Specification 943 NBR IEC - 18(d)
Cable protection:
According to C.S.A. C. No. 182-1 paras. 7.3
Type of Cables:
According to U.L.62 and C.S.A.C22.2 n° 49
Corrosion Resistance: (Plastic Parts)
Salt Spray, Alcohol, Oil, Solvents, Lubricants, Fats, Acid Media, Alkaline and Other Chemical Agents.
Nickel Contacts:
Add NQ after the code
*Merely illustrative image
They follow the main international standards, being used in all ports of the world.
Primary materials:
Housing, Lodging, Pressing and Tension Relief: Self-extinguishing Thermoplastic (C.S.A. C-22.2 n° 6 and U.L. 94 HB-Mil spec ).
Traba-Subtapa and Tuerca Tape Work: Polyamide 6.6.
Seals and Guarniciones: SBR (Neoprene under consultation).
Terminals: Solid brass.
Operation temperature:
0 / 120°C continuous work.
200°C (30 minutes).
Construction:
According to NBR IEC , IEC , DIN , DIN , CEE 17-BS4343 and VDE 0623 CE , NFC SEMKO 117.
Maximum work voltage:
690 Volts RMS - According to NBR IEC
Identification of Terminals:
According to U.L., CSA and NBR IEC
Arc Resistance:
According to C.S.A., C (1990)
Highly insulating (up to 750V - 500Hz)
Dieléctrica Rigidity
NBR IEC
Impact Resistance:
According to C.S.A. C22.2 No. 182-1 paras. 7.4.2 and 7.4.4
Abrasion resistance:
According to C.S.A. C22.2 No. 182-1 paras. 7.4.3 and 7.4
Estanqueity:
The water test according to C.S.A C22.2 - Specification 943 NBR IEC - 18(d)
Cable protection:
According to C.S.A. C. No. 182-1 paras. 7.3
Type of Cables:
According to U.L.62 and C.S.A.C22.2 n° 49
Corrosion Resistance: (Plastic Parts)
Salt Spray, Alcohol, Oil, Solvents, Lubricants, Fats, Acid Media, Alkaline and Other Chemical Agents.
Nickel Contacts:
Add NQ after the code
*Merely illustrative image